000 04000naa a22004697i 4500
001 UMUN-OA-20261005-MLS-037
003 local
005 20261005174904.0
006 m o d
007 cr||||||||||||
008 261005s2015 xx o u000 0 eng d
024 7 _a10.1371/journal.pone.0127117
_2doi
035 _a(local)EuropePMC:PMC4431798
040 _alocal
_beng
_clocal
041 0 _aeng
100 0 _aHua-Rong Huang
_eauthor.
245 1 0 _aEvaluation of a new cryptococcal antigen lateral flow immunoassay in serum, cerebrospinal fluid and urine for the diagnosis of cryptococcosis: a meta-analysis and systematic review. /
_cHua-Rong Huang; Li-Chao Fan; Bhavana Rajbanshi [and others].
264 1 _a[Place of publication not identified] :
_bPLOS,
_c2015.
300 _a1 online resource (1 article).
336 _atext
_btxt
_2rdacontent
337 _acomputer
_bc
_2rdamedia
338 _aonline resource
_bcr
_2rdacarrier
500 _aPublication type: Review article.
500 _aLinked open-access copy: published version.
506 0 _aOpen access; no subscription required for the linked open-access version.
_fUnrestricted online access
_2star
520 3 _aBackground A new lateral flow immunoassay (LFA) for the detection of cryptococcal antigen was developed. Objective We aimed to systematically review all relevant studies to evaluate the diagnostic accuracy of the cryptococcal antigen LFA on serum, CSF and urine specimens. Methods We searched public databases including PubMed, Web of Science, Elsevier Science Direct and Cochrane Library for the English-language literature published up to September 2014. We conducted meta-analyses of sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR) and diagnostic odds ratios (DOR) and SROC of LFA in serum and CSF, respectively. The sensitivity of LFA in urine was also analyzed. Subgroup analyses were carried out to analyze the potential heterogeneity. Results 12 studies were included in this study. The pooled sensitivity and specificity values of LFA in serum were 97.6% (95% CI, 95.6% to 98.9%) and 98.1% (95% CI, 97.4% to 98.6%), respectively. The average PLR of LFA in serum was 43.787 (95% CI, 22.60-84.81) and the NLR was 0.03 (95% CI, 0.01-0.09). The pooled DOR was 2180.30 (95% CI, 868.92-5471.00) and the AUC was 0.9968. The pooled sensitivity and specificity values of LFA in CSF were 98.9% (95% CI, 97.9% to 99.5%) and 98.9% (95% CI, 98.0% to 99.5%), respectively. The average PLR of LFA in serum was 48.83 (95% CI, 21.59-110.40) and the NLR was 0.02 (95% CI, 0.01-0.04). The pooled DOR was 2931.10 (95% CI, 1149.20-7475.90) and the AUC was 0.9974. The pooled sensitivity value of LFA in urine was 85.0% (95% CI, 78.7% to 90.1%). Conclusions The study demonstrates a very high accuracy of LFA in serum and CSF for the diagnosis of cryptococcosis in patients at risk. LFA in urine can be a promising sample screening tool for early diagnosis of cryptococcosis.
540 _aCreative Commons Attribution. See the linked licence for the applicable terms.
_uhttp://creativecommons.org/licenses/by/4.0/
546 _aIn English.
588 0 _aDescription generated from Europe PMC bibliographic metadata retrieved on 5 October 2026; full text linked from the source.
590 _aCourse allocation: B. Sc. Medical Laboratory Science.
653 _aB. Sc. Medical Laboratory Science
653 _aUMUN open access collection
653 _aimmunoassay
655 4 _aReview articles.
700 0 _aLi-Chao Fan
_eauthor.
700 0 _aBhavana Rajbanshi
_eauthor.
700 0 _aJin-Fu Xu
_eauthor.
773 0 _tPloS one
_gVol. 10, no. 5, (2015), pages/article e0127117
_x1932-6203
856 4 0 _uhttps://europepmc.org/articles/PMC4431798
_yRead open-access publication
_zOpen access.
_70
884 _aCourse selection and automated MARC21 enrichment from Europe PMC metadata.
_g20261005
_khttps://europepmc.org/articles/PMC4431798
_qlocal
942 _n0
999 _c1179
_d1179