A systematic review on the rotational thrombelastometry (ROTEM®) values for the diagnosis of coagulopathy, prediction and guidance of blood transfusion and prediction of mortality in trauma patients. / (Record no. 1196)
[ view plain ]
| 000 -LEADER | |
|---|---|
| fixed length control field | 05124naa a22005417i 4500 |
| 001 - CONTROL NUMBER | |
| control field | UMUN-OA-20261005-MLS-054 |
| 003 - CONTROL NUMBER IDENTIFIER | |
| control field | local |
| 005 - DATE AND TIME OF LATEST TRANSACTION | |
| control field | 20261005174905.0 |
| 006 - FIXED-LENGTH DATA ELEMENTS--ADDITIONAL MATERIAL CHARACTERISTICS | |
| fixed length control field | m o d |
| 007 - PHYSICAL DESCRIPTION FIXED FIELD--GENERAL INFORMATION | |
| fixed length control field | cr|||||||||||| |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
| fixed length control field | 261005s2016 xx o u000 0 eng d |
| 024 7# - OTHER STANDARD IDENTIFIER | |
| Standard number or code | 10.1186/s13049-016-0308-2 |
| Source of number or code | doi |
| 035 ## - SYSTEM CONTROL NUMBER | |
| System control number | (local)EuropePMC:PMC5048662 |
| 040 ## - CATALOGING SOURCE | |
| Original cataloging agency | local |
| Language of cataloging | eng |
| Transcribing agency | local |
| 041 0# - LANGUAGE CODE | |
| Language code of text/sound track or separate title | eng |
| 100 0# - MAIN ENTRY--PERSONAL NAME | |
| Personal name | Precilla V Veigas |
| Relator term | author. |
| 245 12 - TITLE STATEMENT | |
| Title | A systematic review on the rotational thrombelastometry (ROTEM®) values for the diagnosis of coagulopathy, prediction and guidance of blood transfusion and prediction of mortality in trauma patients. / |
| Statement of responsibility, etc. | Precilla V Veigas; Jeannie Callum; Sandro Rizoli [and others]. |
| 264 #1 - PRODUCTION, PUBLICATION, DISTRIBUTION, MANUFACTURE, AND COPYRIGHT NOTICE | |
| Place of production, publication, distribution, manufacture | [Place of publication not identified] : |
| Name of producer, publisher, distributor, manufacturer | BMC, |
| Date of production, publication, distribution, manufacture, or copyright notice | 2016. |
| 300 ## - PHYSICAL DESCRIPTION | |
| Extent | 1 online resource (1 article). |
| 336 ## - CONTENT TYPE | |
| Content type term | text |
| Content type code | txt |
| Source | rdacontent |
| 337 ## - MEDIA TYPE | |
| Media type term | computer |
| Media type code | c |
| Source | rdamedia |
| 338 ## - CARRIER TYPE | |
| Carrier type term | online resource |
| Carrier type code | cr |
| Source | rdacarrier |
| 500 ## - GENERAL NOTE | |
| General note | Publication type: Review article. |
| 500 ## - GENERAL NOTE | |
| General note | Linked open-access copy: published version. |
| 506 0# - RESTRICTIONS ON ACCESS NOTE | |
| Terms governing access | Open access; no subscription required for the linked open-access version. |
| Standardized terminology for access restriction | Unrestricted online access |
| Source of term | star |
| 520 3# - SUMMARY, ETC. | |
| Summary, etc. | Introduction Viscoelastic assays have been promoted as an improvement over traditional coagulation tests in the management of trauma patients. Rotational thromboelastometry (ROTEM®) has been used to diagnose coagulopathy and guide hemostatic therapy in trauma. This systematic review of clinical studies in trauma investigates the ROTEM® parameters thresholds used for the diagnosing coagulopathy, predicting and guiding transfusion and predicting mortality. Methods Systematic literature search was performed using MEDLINE, EMBASE and Cochrane databases. We included studies without restricting year of publication, language or geographic location. Original studies reporting the thresholds of ROTEM® parameters in the diagnosis or management of coagulopathy in trauma patients were included. Data on patient demographics, measures of coagulopathy, transfusion and mortality were extracted. We reported our findings according to the Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) guidelines. Quality assessment and risk of bias were performed using Newcastle Ottawa Scale (NOS) and the quality assessment of diagnostic accuracy studies (QUADAS-2) tools, respectively. Results A total of 13 observational studies involving 2835 adult trauma patients met the inclusion criteria. Nine studies were prospective and four were retrospective. There were no randomized controlled trials. The quality of the included studies was moderate (mean NOS 5.92, standard deviation 0.26). Using QUADAS-2, only 1 study (7.6 %) had low risk of bias in all domains, and 9 studies (69.2 %) had low risk of applicability concerns. Outcomes from 13 studies were grouped into three categories: diagnosis of coagulopathy (n = 10), prediction of massive transfusion or transfusion guidance (n = 6) and prediction of mortality (n = 6). Overall, specific ROTEM® parameters measured (clot amplitude and lysis) in the extrinsically activated test (EXTEM) and the fibrin-based extrinsically activated test (FIBTEM) were consistently associated with the diagnosis of coagulopathy, increased risk of bleeding and massive transfusion, and prediction of mortality. Presence of hyperfibrinolysis by ROTEM® was associated with increased mortality. Conclusions Most of the evidence indicates that abnormal EXTEM and FIBTEM clot amplitude (CA5, CA10) or maximal clot firmness (MCF) diagnose coagulopathy, and predict blood transfusion and mortality. The presence of fibrinolysis (abnormal lysis index [LI30] or maximum lysis [ML]) was also associated with mortality. ROTEM® thus, may be of value in the early management of trauma patients. |
| 540 ## - TERMS GOVERNING USE AND REPRODUCTION NOTE | |
| Terms governing use and reproduction | Creative Commons Attribution. See the linked licence for the applicable terms. |
| Uniform Resource Identifier | <a href="http://creativecommons.org/licenses/by/4.0/">http://creativecommons.org/licenses/by/4.0/</a> |
| 546 ## - LANGUAGE NOTE | |
| Language note | In English. |
| 588 0# - SOURCE OF DESCRIPTION NOTE | |
| Source of description note | Description generated from Europe PMC bibliographic metadata retrieved on 5 October 2026; full text linked from the source. |
| 590 ## - LOCAL NOTE (RLIN) | |
| Local note | Course allocation: B. Sc. Medical Laboratory Science. |
| 650 #4 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | Threshold |
| 650 #4 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | Bleeding |
| 650 #4 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | Transfusion |
| 650 #4 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | Thromboelastometry |
| 650 #4 - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | Acute Trauma Coagulopathy |
| 653 ## - INDEX TERM--UNCONTROLLED | |
| Uncontrolled term | B. Sc. Medical Laboratory Science |
| 653 ## - INDEX TERM--UNCONTROLLED | |
| Uncontrolled term | UMUN open access collection |
| 653 ## - INDEX TERM--UNCONTROLLED | |
| Uncontrolled term | blood transfusion |
| 655 #4 - INDEX TERM--GENRE/FORM | |
| Genre/form data or focus term | Review articles. |
| 700 0# - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Jeannie Callum |
| Relator term | author. |
| 700 0# - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Sandro Rizoli |
| Relator term | author. |
| 700 0# - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Bartolomeu Nascimento |
| Relator term | author. |
| 700 0# - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Luis Teodoro da Luz |
| Relator term | author. |
| 773 0# - HOST ITEM ENTRY | |
| Title | Scandinavian journal of trauma, resuscitation and emergency medicine |
| Related parts | Vol. 24, no. 1, (2016), pages/article 114 |
| International Standard Serial Number | 1757-7241 |
| 856 40 - ELECTRONIC LOCATION AND ACCESS | |
| Uniform Resource Identifier | <a href="https://europepmc.org/articles/PMC5048662">https://europepmc.org/articles/PMC5048662</a> |
| Link text | Read open-access publication |
| Public note | Open access. |
| Access status | 0 |
| 884 ## - DESCRIPTION CONVERSION INFORMATION | |
| Conversion process | Course selection and automated MARC21 enrichment from Europe PMC metadata. |
| Conversion date | 20261005 |
| Identifier of source metadata | https://europepmc.org/articles/PMC5048662 |
| Conversion agency | local |
| 942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
| Suppress in OPAC | No |
No items available.