Interventions to prevent iatrogenic anemia: a Laboratory Medicine Best Practices systematic review. / (Record no. 1189)

MARC details
000 -LEADER
fixed length control field 05151naa a22006377i 4500
001 - CONTROL NUMBER
control field UMUN-OA-20261005-MLS-047
003 - CONTROL NUMBER IDENTIFIER
control field local
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20261005174905.0
006 - FIXED-LENGTH DATA ELEMENTS--ADDITIONAL MATERIAL CHARACTERISTICS
fixed length control field m o d
007 - PHYSICAL DESCRIPTION FIXED FIELD--GENERAL INFORMATION
fixed length control field cr||||||||||||
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 261005s2019 xx o u000 0 eng d
024 7# - OTHER STANDARD IDENTIFIER
Standard number or code 10.1186/s13054-019-2511-9
Source of number or code doi
035 ## - SYSTEM CONTROL NUMBER
System control number (local)EuropePMC:PMC6688222
040 ## - CATALOGING SOURCE
Original cataloging agency local
Language of cataloging eng
Transcribing agency local
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title eng
100 0# - MAIN ENTRY--PERSONAL NAME
Personal name Nedra S Whitehead
Relator term author.
245 10 - TITLE STATEMENT
Title Interventions to prevent iatrogenic anemia: a Laboratory Medicine Best Practices systematic review. /
Statement of responsibility, etc. Nedra S Whitehead; Laurina O Williams; Sreelatha Meleth [and others].
264 #1 - PRODUCTION, PUBLICATION, DISTRIBUTION, MANUFACTURE, AND COPYRIGHT NOTICE
Place of production, publication, distribution, manufacture [Place of publication not identified] :
Name of producer, publisher, distributor, manufacturer BMC,
Date of production, publication, distribution, manufacture, or copyright notice 2019.
300 ## - PHYSICAL DESCRIPTION
Extent 1 online resource (1 article).
336 ## - CONTENT TYPE
Content type term text
Content type code txt
Source rdacontent
337 ## - MEDIA TYPE
Media type term computer
Media type code c
Source rdamedia
338 ## - CARRIER TYPE
Carrier type term online resource
Carrier type code cr
Source rdacarrier
500 ## - GENERAL NOTE
General note The source lists 15 contributors; the first 12 names are recorded as access points. The complete source author list is retained in the catalogue manifest.
500 ## - GENERAL NOTE
General note Publication type: Review article.
500 ## - GENERAL NOTE
General note Linked open-access copy: published version.
506 0# - RESTRICTIONS ON ACCESS NOTE
Terms governing access Open access; no subscription required for the linked open-access version.
Standardized terminology for access restriction Unrestricted online access
Source of term star
520 3# - SUMMARY, ETC.
Summary, etc. Background As many as 90% of patients develop anemia by their third day in an intensive care unit (ICU). We evaluated the efficacy of interventions to reduce phlebotomy-related blood loss on the volume of blood lost, hemoglobin levels, transfusions, and incidence of anemia. Methods We conducted a systematic review and meta-analysis using the Laboratory Medicine Best Practices (LMBP) systematic review methods for rating study quality and assessing the body of evidence. Searches of PubMed, Embase, Cochrane, Web of Science, PsychINFO, and CINAHL identified 2564 published references. We included studies of the impact of interventions to reduce phlebotomy-related blood loss on blood loss, hemoglobin levels, transfusions, or anemia among hospital inpatients. We excluded studies not published in English and studies that did not have a comparison group, did not report an outcome of interest, or were rated as poor quality. Twenty-one studies met these criteria. We conducted a meta-analysis if > 2 homogenous studies reported sufficient information for analysis. Results We found moderate, consistent evidence that devices that return blood from flushing venous or arterial lines to the patient reduced blood loss by approximately 25% in both neonatal ICU (NICU) and adult ICU patients [pooled estimate in adults, 24.7 (95% CI = 12.1-37.3)]. Bundled interventions that included blood conservation devices appeared to reduce blood loss by at least 25% (suggestive evidence). The evidence was insufficient to determine if these devices reduced hemoglobin decline or risk of anemia. The evidence suggested that small volume tubes reduced the risk of anemia, but was insufficient to determine if they affected the volume of blood loss or the rate of hemoglobin decline. Conclusions Moderate, consistent evidence indicated that devices that return blood from testing or flushing lines to the patient reduce the volume of blood loss by approximately 25% among ICU patients. The results of this systematic review support the use of blood conservation systems with arterial or venous catheters to eliminate blood waste when drawing blood for testing. The evidence was insufficient to conclude the devices impacted hemoglobin levels or transfusion rates. The use of small volume tubes may reduce the risk of anemia.
540 ## - TERMS GOVERNING USE AND REPRODUCTION NOTE
Terms governing use and reproduction Creative Commons Attribution. See the linked licence for the applicable terms.
Uniform Resource Identifier <a href="http://creativecommons.org/licenses/by/4.0/">http://creativecommons.org/licenses/by/4.0/</a>
546 ## - LANGUAGE NOTE
Language note In English.
588 0# - SOURCE OF DESCRIPTION NOTE
Source of description note Description generated from Europe PMC bibliographic metadata retrieved on 5 October 2026; full text linked from the source.
590 ## - LOCAL NOTE (RLIN)
Local note Course allocation: B. Sc. Medical Laboratory Science.
650 #4 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Anemia
650 #4 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Phlebotomy
650 #4 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Clinical Laboratory Techniques
650 #4 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Blood Conservation Strategy
650 #4 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Iatrogenic Diseases
653 ## - INDEX TERM--UNCONTROLLED
Uncontrolled term B. Sc. Medical Laboratory Science
653 ## - INDEX TERM--UNCONTROLLED
Uncontrolled term UMUN open access collection
653 ## - INDEX TERM--UNCONTROLLED
Uncontrolled term clinical chemistry
655 #4 - INDEX TERM--GENRE/FORM
Genre/form data or focus term Review articles.
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Laurina O Williams
Relator term author.
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Sreelatha Meleth
Relator term author.
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Sara M Kennedy
Relator term author.
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Nneka Ubaka-Blackmoore
Relator term author.
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Sharon M Geaghan
Relator term author.
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name James H Nichols
Relator term author.
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Patrick Carroll
Relator term author.
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Michael T McEvoy
Relator term author.
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Julie Gayken
Relator term author.
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Dennis J Ernst
Relator term author.
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Christine Litwin
Relator term author.
773 0# - HOST ITEM ENTRY
Title Critical care (London, England)
Related parts Vol. 23, no. 1, (2019), pages/article 278
International Standard Serial Number 1364-8535
856 40 - ELECTRONIC LOCATION AND ACCESS
Uniform Resource Identifier <a href="https://europepmc.org/articles/PMC6688222">https://europepmc.org/articles/PMC6688222</a>
Link text Read open-access publication
Public note Open access.
Access status 0
884 ## - DESCRIPTION CONVERSION INFORMATION
Conversion process Course selection and automated MARC21 enrichment from Europe PMC metadata.
Conversion date 20261005
Identifier of source metadata https://europepmc.org/articles/PMC6688222
Conversion agency local
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Suppress in OPAC No

No items available.