Evaluation of a new cryptococcal antigen lateral flow immunoassay in serum, cerebrospinal fluid and urine for the diagnosis of cryptococcosis: a meta-analysis and systematic review. / (Record no. 1179)
[ view plain ]
| 000 -LEADER | |
|---|---|
| fixed length control field | 04000naa a22004697i 4500 |
| 001 - CONTROL NUMBER | |
| control field | UMUN-OA-20261005-MLS-037 |
| 003 - CONTROL NUMBER IDENTIFIER | |
| control field | local |
| 005 - DATE AND TIME OF LATEST TRANSACTION | |
| control field | 20261005174904.0 |
| 006 - FIXED-LENGTH DATA ELEMENTS--ADDITIONAL MATERIAL CHARACTERISTICS | |
| fixed length control field | m o d |
| 007 - PHYSICAL DESCRIPTION FIXED FIELD--GENERAL INFORMATION | |
| fixed length control field | cr|||||||||||| |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
| fixed length control field | 261005s2015 xx o u000 0 eng d |
| 024 7# - OTHER STANDARD IDENTIFIER | |
| Standard number or code | 10.1371/journal.pone.0127117 |
| Source of number or code | doi |
| 035 ## - SYSTEM CONTROL NUMBER | |
| System control number | (local)EuropePMC:PMC4431798 |
| 040 ## - CATALOGING SOURCE | |
| Original cataloging agency | local |
| Language of cataloging | eng |
| Transcribing agency | local |
| 041 0# - LANGUAGE CODE | |
| Language code of text/sound track or separate title | eng |
| 100 0# - MAIN ENTRY--PERSONAL NAME | |
| Personal name | Hua-Rong Huang |
| Relator term | author. |
| 245 10 - TITLE STATEMENT | |
| Title | Evaluation of a new cryptococcal antigen lateral flow immunoassay in serum, cerebrospinal fluid and urine for the diagnosis of cryptococcosis: a meta-analysis and systematic review. / |
| Statement of responsibility, etc. | Hua-Rong Huang; Li-Chao Fan; Bhavana Rajbanshi [and others]. |
| 264 #1 - PRODUCTION, PUBLICATION, DISTRIBUTION, MANUFACTURE, AND COPYRIGHT NOTICE | |
| Place of production, publication, distribution, manufacture | [Place of publication not identified] : |
| Name of producer, publisher, distributor, manufacturer | PLOS, |
| Date of production, publication, distribution, manufacture, or copyright notice | 2015. |
| 300 ## - PHYSICAL DESCRIPTION | |
| Extent | 1 online resource (1 article). |
| 336 ## - CONTENT TYPE | |
| Content type term | text |
| Content type code | txt |
| Source | rdacontent |
| 337 ## - MEDIA TYPE | |
| Media type term | computer |
| Media type code | c |
| Source | rdamedia |
| 338 ## - CARRIER TYPE | |
| Carrier type term | online resource |
| Carrier type code | cr |
| Source | rdacarrier |
| 500 ## - GENERAL NOTE | |
| General note | Publication type: Review article. |
| 500 ## - GENERAL NOTE | |
| General note | Linked open-access copy: published version. |
| 506 0# - RESTRICTIONS ON ACCESS NOTE | |
| Terms governing access | Open access; no subscription required for the linked open-access version. |
| Standardized terminology for access restriction | Unrestricted online access |
| Source of term | star |
| 520 3# - SUMMARY, ETC. | |
| Summary, etc. | Background A new lateral flow immunoassay (LFA) for the detection of cryptococcal antigen was developed. Objective We aimed to systematically review all relevant studies to evaluate the diagnostic accuracy of the cryptococcal antigen LFA on serum, CSF and urine specimens. Methods We searched public databases including PubMed, Web of Science, Elsevier Science Direct and Cochrane Library for the English-language literature published up to September 2014. We conducted meta-analyses of sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR) and diagnostic odds ratios (DOR) and SROC of LFA in serum and CSF, respectively. The sensitivity of LFA in urine was also analyzed. Subgroup analyses were carried out to analyze the potential heterogeneity. Results 12 studies were included in this study. The pooled sensitivity and specificity values of LFA in serum were 97.6% (95% CI, 95.6% to 98.9%) and 98.1% (95% CI, 97.4% to 98.6%), respectively. The average PLR of LFA in serum was 43.787 (95% CI, 22.60-84.81) and the NLR was 0.03 (95% CI, 0.01-0.09). The pooled DOR was 2180.30 (95% CI, 868.92-5471.00) and the AUC was 0.9968. The pooled sensitivity and specificity values of LFA in CSF were 98.9% (95% CI, 97.9% to 99.5%) and 98.9% (95% CI, 98.0% to 99.5%), respectively. The average PLR of LFA in serum was 48.83 (95% CI, 21.59-110.40) and the NLR was 0.02 (95% CI, 0.01-0.04). The pooled DOR was 2931.10 (95% CI, 1149.20-7475.90) and the AUC was 0.9974. The pooled sensitivity value of LFA in urine was 85.0% (95% CI, 78.7% to 90.1%). Conclusions The study demonstrates a very high accuracy of LFA in serum and CSF for the diagnosis of cryptococcosis in patients at risk. LFA in urine can be a promising sample screening tool for early diagnosis of cryptococcosis. |
| 540 ## - TERMS GOVERNING USE AND REPRODUCTION NOTE | |
| Terms governing use and reproduction | Creative Commons Attribution. See the linked licence for the applicable terms. |
| Uniform Resource Identifier | <a href="http://creativecommons.org/licenses/by/4.0/">http://creativecommons.org/licenses/by/4.0/</a> |
| 546 ## - LANGUAGE NOTE | |
| Language note | In English. |
| 588 0# - SOURCE OF DESCRIPTION NOTE | |
| Source of description note | Description generated from Europe PMC bibliographic metadata retrieved on 5 October 2026; full text linked from the source. |
| 590 ## - LOCAL NOTE (RLIN) | |
| Local note | Course allocation: B. Sc. Medical Laboratory Science. |
| 653 ## - INDEX TERM--UNCONTROLLED | |
| Uncontrolled term | B. Sc. Medical Laboratory Science |
| 653 ## - INDEX TERM--UNCONTROLLED | |
| Uncontrolled term | UMUN open access collection |
| 653 ## - INDEX TERM--UNCONTROLLED | |
| Uncontrolled term | immunoassay |
| 655 #4 - INDEX TERM--GENRE/FORM | |
| Genre/form data or focus term | Review articles. |
| 700 0# - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Li-Chao Fan |
| Relator term | author. |
| 700 0# - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Bhavana Rajbanshi |
| Relator term | author. |
| 700 0# - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Jin-Fu Xu |
| Relator term | author. |
| 773 0# - HOST ITEM ENTRY | |
| Title | PloS one |
| Related parts | Vol. 10, no. 5, (2015), pages/article e0127117 |
| International Standard Serial Number | 1932-6203 |
| 856 40 - ELECTRONIC LOCATION AND ACCESS | |
| Uniform Resource Identifier | <a href="https://europepmc.org/articles/PMC4431798">https://europepmc.org/articles/PMC4431798</a> |
| Link text | Read open-access publication |
| Public note | Open access. |
| Access status | 0 |
| 884 ## - DESCRIPTION CONVERSION INFORMATION | |
| Conversion process | Course selection and automated MARC21 enrichment from Europe PMC metadata. |
| Conversion date | 20261005 |
| Identifier of source metadata | https://europepmc.org/articles/PMC4431798 |
| Conversion agency | local |
| 942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
| Suppress in OPAC | No |
No items available.